The 60Hz Prime output 500KVA 450kva KANPOR KANGMINGSI KTA19G2 Diesel Generator is a top-of-the-line power solution. It features a compact structure, making it easy to install in tight spaces. It is also equipped with a reliable performance, ensuring your power needs are met. With its high-efficiency engine, it can provide clean, stable power to keep your operations running smoothly. The generator is also designed to be fuel-efficient, saving you money in the long run.
60Hz Prime output 450kva KANPOR KANGMINGSI KTA19G2 Diesel Generator
Model: | KPC500 |
---|---|
Prime Power (kw/kva ) | 360kw/450kva |
Standby Power(kw /kva ) | 400kw/500kva |
Rated Voltage | 230v/400v (Adjustable) |
Frequency | 60Hz |
Radiator | 50°C suitable for tropical weather |
Power Factor | 0.8(lagging) |
Fuel: | Diesel |
Start Method: | 24V DC Start Battery |
Accessory: | Battery, wire, exhaust pipe, muffler, damper, breaker |
Altitude: | ≤1000m |
Base Feul Tank Capacity | Enough for Genset 8-10 Hours Continuous Running |
Engine Specifications | |
Brand & Model | CCEC KANPOR KANGMINGSI KTA19G2 |
Country of Origin | USA joint-venture with china |
Cycle | 4 stroke |
Engine power (kwm) | 448kw |
Air intake way | Turbo |
Governor | Electronic |
Cylinder | 6 |
Bore*Stroke (mm) | 159*159 |
Displacement (L) | 18.9 |
Compression Ratio | 13.9:1 |
Total coolant capacity (L) | 30 |
Lubrication capacity (L) | 16.8 |
Fuel system | fuel pump |
Frequency & Speed | 60Hz, 1800RPM |
Cooling way | Water cooled |
Fuel consumption | 203g/kw.h <98L/H> |
Starting Method | DC24V electrical starting |
Cooling System: | Forced water cooling cycle |
Alternator Specifications | |
Alternator brand | KANPOR STAMFORD(HK) |
Model | HCI314E/360KW |
Power Factor(COS Phi) | 0.8 |
Excite Type | Brushless SHUNT,AC Synchronous,Double bearing |
Connecting Type | 3 Phase & 4 Wires |
Insulation Degree | H |
Enclosure Degree | IP23 |
AVR voltage regulation rate | ≤±0.5% |
Voltage Regulation, Steady State | ≤±0.5% |
Transient State Voltage | ≤-15%~+20% |
Exciter Type: | Brushless, self-exciting, with AVR |
Insulation Class, Temperature Rise: | H/H |
Voltage Regulation: | ≥±5% |
ATS | Option |
Brand & Model | AISHIKAI 650A |
Control System Specifications | |
Main Features: | a) Instruments:Analogue Volmeter,Hours Run Meter.Water pressure Meter. b) Controls:Emergency Stop Pushbutton,Volmeter Phase Selector Switch. |
Manufacturer: | SMARTGEN |
Model: | HGM6110 / HGM6120 |
Type: | Manual / Auto Operation |
Operation: | Via a three position key switch ;with STOP(O), RUN(I) and START(II). |
Alarm Protect: | Low Oil Pressure, High Engine Temperature, Auxiliary Shutdown, Charge Failure |
Δ Automatic mains failure | Δ Mains simulation |
Δ Engine control,Generator protection | Δ Block heater control |
Δ Built in alarms and warnings | Δ Field adjustable parameters |
Δ Remote Start operation available | Δ Free MS-Windows Remote monitoring |
Δ Daily / weekly / monthly exerciser | Δ LED displays |
Δ Weekly operation schedule programs | Δ Configurable analogue inputs |
Δ Fuel pump control | Δ I/O expansion capability |
Δ ECU control and monitoring via J1940 CANBUS | D+ preexcitation terminal |
AUTOMATIC MAINS FAILURE | 7 binary inputs and outputs |
Size and Weight | |
Open Type Overall Size: | 3370mm*1220mm*1900mm |
Weight: | 3250 KG |
Soundproof Type Overall Size: | 4300mm*1500mm*2400mm |
Weight: | 4600kgs |
Low Harmful Emissions: The 60Hz Prime output 500KVA 450kva KANPOR KANGMINGSI KTA19G2 Diesel Generator is designed to emit low levels of harmful emissions. This makes it an environmentally friendly option, as it helps to reduce the impact of the generator on the environment. The diesel engine is designed to meet strict emission standards, ensuring that it produces low levels of pollutants and particulate matter.
Good Fire Safety: The generator is designed with good fire safety features, including many safety measures. This helps to prevent fires and reduce the risk of damage to the generator or surrounding equipment. The generator is also designed to be safe to operate, with safety features that prevent accidents and ensure that it can be used safely in a variety of settings.
Δ Engine part | Δ Alternator part | Δ Electrical part | Δ Others |
---|---|---|---|
- Electronic commissioning (for mechanical commissioning engine) - External oil water separator - Water jacket / oil heater - Lubricating oil pre-feed pump |
-PMG (Permanent Magnet Excitation System) below 600KW - Drooping device - External potentiometer - Anti-condensation heater -High-grade AVR (automatic voltage regulator) |
- Automatic Dual Power -Switching Cabinet (ATS) - Automatic parallel (grid) cabinet - DELIXI main circuit breaker |
- Chassis / independent storage tank - Fixed / mobile silent box |
Q1: What is your warranty period?
A: Our warranty is 1 year or 1200 running hours whichever comes first. But based on some special project, we can extended our warranty period.
Q2: How to transport your goods to us?
A: By air / by sea. LCL & FCL. Generally, we load goods in 20FT/40HQ container by sea.
Q3: How to package your goods?
A: Small one By carton / Middle one by plywood / Big one by seaworthy plastic with foam.
Q4: What is the delivery lead time?
A: Products in stock: 1-3 days. New production products: Open type: 2-3 weeks; Silent type: 3-4 weeks; Container type: 4-5 weeks.